DIN1.FILTER TO DIN7.FILTER

DIN1.FILTER TO DIN3.FILTER

Description

This parameter sets the digital input filter configuration for channel x when followed with the values defined below. DINx.FILTER retrieves this information when not followed by data.

Value

Description

DINX.FILTER 0

The drive digital input channel detects all input signals with an input pulse width of ≥ 40 ns (no filtering applied).

DINX.FILTER 1

The drive digital input channel detects all input signals with an input pulse width of ≥ 10.24 µs, ± 0.64 µs (fast filter applied).

DINX.FILTER 2

The drive digital input channel detects all input signals with an input pulse width of ≥ 163 µs, ± 10.24 µs (standard filter applied).

DINX.FILTER 3

The drive digital input channel detects all input signals with an input pulse width of ≥ 2.62 ms, ± 0.16384 ms (slow filter applied).

General Information

DIN1.FILTER to DIN2.FILTER

Type

R/W Parameter

Units

N/A

Range

0 to 3

Default Value

1 for DIN1 and DIN2

2 for DIN3 to DIN7

2 for DIN3

Data Type

Integer

Start Version

M_01-03-07-000

FieldbusClosedA Fieldbus is an industrial network system for real-time distributed control (e.g. CAN or Profibus). It is a way of connecting instruments in a plant design Index/Subindex Object Start Version

EtherCATClosedEtherCAT is an open, high-performance Ethernet-based fieldbus system. The development goal of EtherCAT was to apply Ethernet to automation applications which require short data update times (also called cycle times) with low communication jitter (for synchronization purposes) and low hardware costs COE and CANopen

51CBh/0 DIN1.FILTER M_01-03-07-000
51CCh/0 DIN2.FILTER
51CDh/0 DIN3.FILTER
51CEh/0 DIN4.FILTER
51CFh/0 DIN5.FILTER
51D0h/0 DIN6.FILTER
51D1h/0 DIN7.FILTER

Related Topics

Digital Inputs and Outputs