DIN1.FILTER TO DIN7.FILTER
DIN1.FILTER TO DIN3.FILTER
Description
This parameter sets the digital input filter configuration for channel x when followed with the values defined below. DINx.FILTER retrieves this information when not followed by data.
Value |
Description |
---|---|
DINX.FILTER 0 |
The drive digital input channel detects all input signals with an input pulse width of ≥ 40 ns (no filtering applied). |
DINX.FILTER 1 |
The drive digital input channel detects all input signals with an input pulse width of ≥ 10.24 µs, ± 0.64 µs (fast filter applied). |
DINX.FILTER 2 |
The drive digital input channel detects all input signals with an input pulse width of ≥ 163 µs, ± 10.24 µs (standard filter applied). |
DINX.FILTER 3 |
The drive digital input channel detects all input signals with an input pulse width of ≥ 2.62 ms, ± 0.16384 ms (slow filter applied). |
General Information
DIN1.FILTER to DIN2.FILTER
Type |
R/W Parameter |
Units |
N/A |
Range |
0 to 3 |
Default Value |
1 for DIN1 and DIN2 2 for DIN3 to DIN7 2 for DIN3 |
Data Type |
Integer |
Start Version |
M_01-03-07-000 |
FieldbusA Fieldbus is an industrial network system for real-time distributed control (e.g. CAN or Profibus). It is a way of connecting instruments in a plant design | Index/Subindex | Object Start Version | |
---|---|---|---|
51CBh/0 | DIN1.FILTER | M_01-03-07-000 | |
51CCh/0 | DIN2.FILTER | ||
51CDh/0 | DIN3.FILTER | ||
51CEh/0 | DIN4.FILTER | ||
51CFh/0 | DIN5.FILTER | ||
51D0h/0 | DIN6.FILTER | ||
51D1h/0 | DIN7.FILTER |